The LW16-40.5 outdoor SF6 circuit breaker is designed for use in a 50 Hz three-phase AC power system and is suitable for control and protection in industrial enterprises, power plants, and substations. This product is capable of frequent operations and can be used as a link circuit breaker and for switching capacitor banks or reactor banks. The internal current transformers can be used for measurement and protection. It can directly replace the SW2-35 oil circuit breaker and, with the addition of an overcurrent bracket, can replace various models of oil circuit breakers. It is an ideal oil-free circuit breaker for 35 kV power systems.
Note: When the circuit breaker is in hot standby mode, surge arresters must be installed on the fault side of the breaker.
No. Parameter Name Unit Parameter Value 1 Rated voltage kV 40.5 2 1-Minute power frequency withstand voltage kV 95 (Grounded) / 185 (Contact gap) 3 Rated frequency Hz 50 4 Rated current A 1600, 2000 5 Rated short-circuit breaking current kA 25 (reclosing), 31.5 (single separation) 6 Rated short-circuit making current (peak) kA 63 7 Rated short-time withstand current kA 25 8 Rated short circuit duration s 4 9 Rated peak withstand current kA 63 10 Rated operating sequence – O—0.3s—CO—180s—CO 11 Rated switching current for a single capacitor bank A 400 12 Rated out-of-step breaking current kA 6.3 13 Rated out-of-phase breaking current kA 21.75 14 Mechanical life test Times 3000 15 Rated cumulative breaking times (rated current) Times 2000 16 Rated cumulative breaking times (25kA short-circuit) Times 21 17 Tripping time s ≤0.06 (rated/max voltage) / ≤0.10 (min voltage) 18 Closing time s ≤0.15 19 SF6 gas rated pressure (20℃ gauge pressure) MPa 0.60±0.015 20 SF6 gas refill alarm pressure (20℃ gauge pressure) MPa 0.55±0.015 21 SF6 gas minimum functional pressure (20℃ gauge) MPa 0.52±0.015 22 SF6 gas annual leakage rate %/Year ≤1 23 SF6 gas trace moisture content ppm (V/V) ≤150×10⁻⁶ 24 CT14-A mechanism coil rated voltage V DC: 110/220; AC: 220/380 25 SF6 gas weight kg Normal: 2.5; CT: 6; Elevated CT: 8 26 Circuit breaker weight kg 1000 27 External insulation leakage specific distance mm/kV ≥31 28 Porcelain insulator leakage distance mm ≥1255
Notes:
O: Open operation
CO: Close-Open operation
s: Seconds
ppm: Parts per million
CT: Current Transformer configuration
Values with tolerances (e.g., ±0.015) and conditional parameters (e.g., reclosing/single separation) are explicitly stated.
Units standardized (e.g., “kV” for kilovolts, “MPa” for megapascals).
Scientific notation corrected (e.g., “≤150×10⁻⁶” instead of “X10-6”).
Combined entries (e.g., tripping time under different voltages) are merged for clarity.